Brida para sujeción de riostra compatible con tramos STZ35, Galvanizado electrolítico.
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

Brida para sujeción de riostra compatible con tramos STZ35, Galvanizado electrolítico.

Disponible: En Stock
$ 817.37 MXN
Image

Key Features

  • ISO 9000 standards guarantee superior quality
  • Delta type flanges with central support
  • Uniform tension distribution in cables
  • Electrolytic galvanized product for corrosion protection
  • Grade 5 hardware with lock nut

Application

  • For STZ35 section towers
  • Designed to distribute guy wire tension
  • Prevents structure deformation due to improper placement
Standards and Certifications
  • Construction under ISO 9000 standards
Construction
  • Delta type design with central support point
  • Electrolytic galvanized material
  • Includes set of grade 5 hardware
  • Includes lock nut
Functionality
  • Distributes guy wire tension uniformly
  • Prevents structure deformation due to improper placement

Installation Notes

  • For calculating extra guying on towers with a stabilizer, it is assumed that this replaces the flange located at 3/4 of the tower's height or the one closest to this height
  • Guy wire lengths are calculated to place anchors at 70% of the total tower height
  • Distances are only installation recommendations
  • Installation must be performed only by experts
  • It is recommended to carry out a soil resistance study to plan a correct foundation

Download the technical sheet here

Key Features

  • ISO 9000 standards guarantee superior quality
  • Delta type flanges with central support
  • Uniform tension distribution in cables
  • Electrolytic galvanized product for corrosion protection
  • Grade 5 hardware with lock nut

Application

  • For STZ35 section towers
  • Designed to distribute guy wire tension
  • Prevents structure deformation due to improper placement
Standards and Certifications
  • Construction under ISO 9000 standards
Construction
  • Delta type design with central support point
  • Electrolytic galvanized material
  • Includes set of grade 5 hardware
  • Includes lock nut
Functionality
  • Distributes guy wire tension uniformly
  • Prevents structure deformation due to improper placement

Installation Notes

  • For calculating extra guying on towers with a stabilizer, it is assumed that this replaces the flange located at 3/4 of the tower's height or the one closest to this height
  • Guy wire lengths are calculated to place anchors at 70% of the total tower height
  • Distances are only installation recommendations
  • Installation must be performed only by experts
  • It is recommended to carry out a soil resistance study to plan a correct foundation

Download the technical sheet here