Class B surge suppressor with 127/220 Vac operating voltage, 2-phase, 60 KA
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

Class B surge suppressor with 127/220 Vac operating voltage, 2-phase, 60 KA

Disponible: En Stock
$ 9,071.16 MXN
Image

SUPRECTOR Class B transient suppressors are designed to provide the best protection for secondary panels, especially those with critical loads.

SUPRECTOR brand suppressors feature hybrid technology that includes varistors of different capacities to meet various protection needs. In addition, the varistors integrate a high-precision thermal fuse that, in the event of an overcurrent, opens the circuit, preventing flame detachment and short-circuiting of the varistor. They also offer modular protection for easy replacement, repair, and expansion.

Another advantage of SUPRECTOR is its waveform tracking circuit, which filters noise generated by transient voltage clipping.

APPLICATIONS

Class B suppressors are designed to provide protection in secondary or distribution panels.

FEATURES

  • Enclosure: Steel NEMA 4
  • Dimensions: 30 x 20 x 12 cm
  • Operating Voltage: 127/220 Vca
  • Capacity: 60 KA
  • Phases: 2
  • Connection: 4 wires
  • Protection Modes:
  • Line-Neutral (L-N)
  • Line-Ground (L-G)
  • Neutral-Ground (N-G)
  • Line-Line (L-L) (On Request)

OPERATIONAL DIAGNOSIS

  • GREEN = PROTECTED
  • RED = UNPROTECTED
  • LED(s) off = DISCONNECTED. Replace the suppressor module after checking line voltage and installation diagram.

WARRANTY

5 years.


Download the technical sheet here

SUPRECTOR Class B transient suppressors are designed to provide the best protection for secondary panels, especially those with critical loads.

SUPRECTOR brand suppressors feature hybrid technology that includes varistors of different capacities to meet various protection needs. In addition, the varistors integrate a high-precision thermal fuse that, in the event of an overcurrent, opens the circuit, preventing flame detachment and short-circuiting of the varistor. They also offer modular protection for easy replacement, repair, and expansion.

Another advantage of SUPRECTOR is its waveform tracking circuit, which filters noise generated by transient voltage clipping.

APPLICATIONS

Class B suppressors are designed to provide protection in secondary or distribution panels.

FEATURES

  • Enclosure: Steel NEMA 4
  • Dimensions: 30 x 20 x 12 cm
  • Operating Voltage: 127/220 Vca
  • Capacity: 60 KA
  • Phases: 2
  • Connection: 4 wires
  • Protection Modes:
  • Line-Neutral (L-N)
  • Line-Ground (L-G)
  • Neutral-Ground (N-G)
  • Line-Line (L-L) (On Request)

OPERATIONAL DIAGNOSIS

  • GREEN = PROTECTED
  • RED = UNPROTECTED
  • LED(s) off = DISCONNECTED. Replace the suppressor module after checking line voltage and installation diagram.

WARRANTY

5 years.


Download the technical sheet here