{"product_id":"supresor-de-pico-clase-b-con-voltaje-de-operacion-127-220-vca-2-fases-60-ka","title":"Class B surge suppressor with 127\/220 Vac operating voltage, 2-phase, 60 KA","description":"\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003c!-- Imagen principal --\u003e \u003cdiv style=\"width: 100%; margin-bottom: 30px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KDALU\/76017-total_ground.jpg\" alt=\"\"\u003e \u003c\/div\u003e \u003c!-- Descripción general --\u003e \u003cdiv style=\"margin-bottom: 30px; font-size: 15px;\"\u003e \u003cp\u003eSUPRECTOR Class B transient suppressors are designed to provide the best protection for secondary panels, especially those with critical loads.\u003c\/p\u003e \u003cp\u003eSUPRECTOR brand suppressors feature hybrid technology that includes varistors of different capacities to meet various protection needs. In addition, the varistors integrate a high-precision thermal fuse that, in the event of an overcurrent, opens the circuit, preventing flame detachment and short-circuiting of the varistor. They also offer modular protection for easy replacement, repair, and expansion.\u003c\/p\u003e \u003cp\u003eAnother advantage of SUPRECTOR is its waveform tracking circuit, which filters noise generated by transient voltage clipping.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de aplicaciones --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eAPPLICATIONS\u003c\/h3\u003e \u003cp\u003eClass B suppressors are designed to provide protection in secondary or distribution panels.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de características --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFEATURES\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Steel NEMA 4\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 30 x 20 x 12 cm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 127\/220 Vca\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 60 KA\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003ePhases:\u003c\/strong\u003e 2\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eConnection:\u003c\/strong\u003e 4 wires\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\u003cstrong\u003eProtection Modes:\u003c\/strong\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"padding-left: 40px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLine-Neutral (L-N)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLine-Ground (L-G)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eNeutral-Ground (N-G)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLine-Line (L-L) (On Request)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Sección de diagnóstico --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eOPERATIONAL DIAGNOSIS\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cspan style=\"color: #27ae60; font-weight: bold;\"\u003eGREEN\u003c\/span\u003e = PROTECTED\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cspan style=\"color: #c0392b; font-weight: bold;\"\u003eRED\u003c\/span\u003e = UNPROTECTED\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLED(s) off = \u003cstrong\u003eDISCONNECTED\u003c\/strong\u003e. Replace the suppressor module after checking line voltage and installation diagram.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Imagenes adicionales --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SUPR1201FBSO\/76131-supresores_tabla_recomendacion_uso_2.png\" alt=\"\"\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SUPR1201FBSO\/76131-tabla_voltaje_a_b_c.png\" alt=\"\"\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SUPR1201FBSO\/76131-supresor_medidad.png\" alt=\"\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sección de garantía --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eWARRANTY\u003c\/h3\u003e \u003cp\u003e5 years.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Separador final --\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e\u003cp\u003e\u003ca href=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2021\/07\/29\/e377a\/GARANTIA%20EN%20PRODUCTOS%20TG.pdf\" target=\"_blank\"\u003eDownload the technical sheet here\u003c\/a\u003e\u003c\/p\u003e","brand":"Vigilancianetwork 1","offers":[{"title":"Default Title","offer_id":43068835561538,"sku":"SUPR-60-2-FASO","price":9071.16,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/5276\/3714\/files\/SUPR602FASO-p.png?v=1773064641","url":"https:\/\/vigilancianetwork.mx\/es\/products\/supresor-de-pico-clase-b-con-voltaje-de-operacion-127-220-vca-2-fases-60-ka","provider":"Vigilancianetwork","version":"1.0","type":"link"}