Brida para sujeción de retenida compatible con tramos STZ30G, Galvanizado en Caliente.
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

Brida para sujeción de retenida compatible con tramos STZ30G, Galvanizado en Caliente.

Disponible: En Stock
$ 820.01 MXN
Image

Key Features

  • Complies with ISO 9000 standards for exceptional quality
  • Delta type flange with central pivot point
  • Uniform tension distribution on guy wires
  • Hot-dip galvanized for resistance
  • Includes grade 5 hardware and safety nut

Application

  • Designed for STZ30G section towers
  • For installations with guy wires
  • Tension distribution system for guy cables
  • Prevents structural deformation due to improper guy wire placement
Technical Specifications
  • Material: Structural steel
  • Finish: Hot-dip galvanized
  • Configuration: Delta type flange
  • Pivot point: Central
  • Includes: Grade 5 hardware and safety nut
Recommended Applications
  • Installations with heavy loads
  • Installations with large surface antenna loads
  • Installations in areas with strong wind currents
  • Installations requiring uniform tension distribution

Installation Notes

  • Guy wire lengths are calculated to place anchors at 70% of the total tower height
  • Ground anchors can be replaced by SAP01 or SAP01G wall anchors depending on the application
  • Installation must only be performed by qualified personnel
  • A soil resistance study is recommended to plan proper foundation

Installation Dimensions

Tower Height (m) L1 (m) L2 (m) h1 (m) h2 (m) h3 (m) h4 (m) h5 (m)
3 2.1 - 2.5 - - - -
6 4.2 - 5.4 2.7 - - -
9 6.3 - 8.1 4.0 - - -
12 8.4 - 11.0 6.0 - - -
15 10.5 - 14.0 9.0 4.5 - -
18 12.6 - 17.0 11.0 5.6 - -
21 14.7 - 19.5 13.0 6.5 - -
24 16.8 - 23.0 17.5 12.0 6.0 -
27 19.0 - 26.0 19.5 13.0 6.5 -
30 21.0 - 28.5 22.5 17.0 11.5 6.0

Additional Notes

  • Distances are only installation recommendations
  • For calculating extra guy wires on towers with a stabilizer, this replaces the flange located at 3/4 of the tower height or the closest to this height
  • A soil resistance study is recommended to plan proper foundation
  • Obstruction lights are recommended at all times

Download the technical sheet here

Key Features

  • Complies with ISO 9000 standards for exceptional quality
  • Delta type flange with central pivot point
  • Uniform tension distribution on guy wires
  • Hot-dip galvanized for resistance
  • Includes grade 5 hardware and safety nut

Application

  • Designed for STZ30G section towers
  • For installations with guy wires
  • Tension distribution system for guy cables
  • Prevents structural deformation due to improper guy wire placement
Technical Specifications
  • Material: Structural steel
  • Finish: Hot-dip galvanized
  • Configuration: Delta type flange
  • Pivot point: Central
  • Includes: Grade 5 hardware and safety nut
Recommended Applications
  • Installations with heavy loads
  • Installations with large surface antenna loads
  • Installations in areas with strong wind currents
  • Installations requiring uniform tension distribution

Installation Notes

  • Guy wire lengths are calculated to place anchors at 70% of the total tower height
  • Ground anchors can be replaced by SAP01 or SAP01G wall anchors depending on the application
  • Installation must only be performed by qualified personnel
  • A soil resistance study is recommended to plan proper foundation

Installation Dimensions

Tower Height (m) L1 (m) L2 (m) h1 (m) h2 (m) h3 (m) h4 (m) h5 (m)
3 2.1 - 2.5 - - - -
6 4.2 - 5.4 2.7 - - -
9 6.3 - 8.1 4.0 - - -
12 8.4 - 11.0 6.0 - - -
15 10.5 - 14.0 9.0 4.5 - -
18 12.6 - 17.0 11.0 5.6 - -
21 14.7 - 19.5 13.0 6.5 - -
24 16.8 - 23.0 17.5 12.0 6.0 -
27 19.0 - 26.0 19.5 13.0 6.5 -
30 21.0 - 28.5 22.5 17.0 11.5 6.0

Additional Notes

  • Distances are only installation recommendations
  • For calculating extra guy wires on towers with a stabilizer, this replaces the flange located at 3/4 of the tower height or the closest to this height
  • A soil resistance study is recommended to plan proper foundation
  • Obstruction lights are recommended at all times

Download the technical sheet here