Brida para sujeción de retenida compatible con tramos STZ35G, Galvanizado en Caliente.
Brida para sujeción de retenida compatible con tramos STZ35G, Galvanizado en Caliente.
Disponible:
En Stock
- SKU SJB-35G
$ 929.20 MXN
Main Features
- Complies with ISO 9000 standards for superior quality
- Delta type flange with central support
- Uniform tension distribution in cables
- Hot-dip galvanized
- Includes grade 5 hardware and safety nut
Applications
- For STZ35G section towers
- Installations with heavy weight loads
- Large antenna surface loads
- Areas with strong wind currents
Installation Notes
- Installation must be carried out by qualified personnel
- Distances are only installation recommendations
- Guy wire lengths are calculated for anchors at 70% of the height
- Soil resistance study is recommended for foundation
- Floor anchors can be replaced by wall anchors (SAP01 or SAP01G) depending on the application
Dimensions
| Tower Height (m) | L1 (m) | L2 (m) | h1 (m) | h2 (m) | h3 (m) |
|---|---|---|---|---|---|
| 3 | 2.1 | - | 2.5 | - | - |
| 6 | 4.2 | - | 5.4 | 2.7 | - |
| 9 | 6.3 | - | 8.1 | 4.0 | - |
| 12 | 8.4 | - | 11.0 | 6.0 | - |
| 15 | 10.5 | - | 14.0 | 9.0 | 4.5 |
| 18 | 12.6 | - | 17.0 | 11.0 | 5.6 |
Additional Notes
- Towers with stabilizers replace the flange located at 3/4 height
- It is recommended to install obstruction lights at all times
Main Features
- Complies with ISO 9000 standards for superior quality
- Delta type flange with central support
- Uniform tension distribution in cables
- Hot-dip galvanized
- Includes grade 5 hardware and safety nut
Applications
- For STZ35G section towers
- Installations with heavy weight loads
- Large antenna surface loads
- Areas with strong wind currents
Installation Notes
- Installation must be carried out by qualified personnel
- Distances are only installation recommendations
- Guy wire lengths are calculated for anchors at 70% of the height
- Soil resistance study is recommended for foundation
- Floor anchors can be replaced by wall anchors (SAP01 or SAP01G) depending on the application
Dimensions
| Tower Height (m) | L1 (m) | L2 (m) | h1 (m) | h2 (m) | h3 (m) |
|---|---|---|---|---|---|
| 3 | 2.1 | - | 2.5 | - | - |
| 6 | 4.2 | - | 5.4 | 2.7 | - |
| 9 | 6.3 | - | 8.1 | 4.0 | - |
| 12 | 8.4 | - | 11.0 | 6.0 | - |
| 15 | 10.5 | - | 14.0 | 9.0 | 4.5 |
| 18 | 12.6 | - | 17.0 | 11.0 | 5.6 |
Additional Notes
- Towers with stabilizers replace the flange located at 3/4 height
- It is recommended to install obstruction lights at all times