12m Guyed Tower Kit for Floor with Hot-Dip Galvanized STZ35G Section (Guy wires not included).
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

12m Guyed Tower Kit for Floor with Hot-Dip Galvanized STZ35G Section (Guy wires not included).

Disponible: En Stock
$ 23,190.27 MXN
Image
Logo SYSCOM TOWERS

Outstanding Features:

  • Product manufactured under ISO 9001:2015 standards.
  • High Elevation / Low Cost.
  • 100% Inspection of Section-to-Section Assembly.
  • Hot-dip galvanized according to NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal areas or industrial areas.

Physical Characteristics:

  • Maximum Axial Load: 350 kg.
  • Height: 12 meters (4 sections).
  • Wind resistance: 200 km/hr.
  • Corrosion protection: Hot-dip galvanizing (NMX-H-004-SCFI-2008).
  • Application: Outdoors (Humid areas).

Includes the following components:

Quantity Model Description
4 STZ35G Tower section, 35 cm face width.
1 SCZ35PG 35 cm tower top with suppressor for lightning rod.
1 SBZ35G 35 cm tower base.
1 SAB45G Anchor for 35/45 tower base.
2 SJB35G Guy wire clamp.
3 SAZ45G Ground anchor for Guy wire.
12 CUELLO-14-HDG Thimble for guy wire
36 NUDO-316-FJG 3/16' cable clip.

Guy wire not included. 95 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.

Turnbuckles not included. 6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will result in loss of equipment warranty, and any additional adaptations are the responsibility of the installer.


Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. L810 type.
2 HLU3R2 Mounting for EIGSLSE obstruction lamp

*The signaling standard dictates that the tower must be painted in 7 equally sized stripes; 4 stripes in reddish-orange and 3 in white.

Lifeline System (Not included)

Quantity Model Description
1 SHE-LV Pair of fastening hardware
1 S-GULV Line guide
15 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged clip
2 CUELLO-38-HDG 3/8' Thimble
1 TRY-ACC-SLIDER (Optional) Safety Trolley for Installer.
1 SYS-USA7B (Optional) Suspension Harness.

*NOM-009 mandates the use of systems that prevent accidental falls on a structure.

Recommended Grounding System for Tower and Equipment Mounted on it (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box.
3 TGCR11 Eye Connector
2 TGAB18 Rod Connector
1 TGBUSG10 Busbar with 1000A Insulators (Without Enclosure)

* It is recommended to use 4 AWG insulated copper cable (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.

Recommended Basic Lightning Rod System for Tower (Not included)

Quantity Model Description
1 TGTDPC Punta Pararrayo con Mástil de Aluminio (MASTIL1.2)
1 TG45AB Electrodo de 45 Amp. Con un saco de compuesto mejorador de impedancia (H2OHM), brújula y nivel.
1 S610 Registro plástico chico.
1 ANTIOX Aerosol para protección de terminales.
3 TGCR11 Conector de Ojo.
2 TGAB18 Conector para Varilla.
8 TGAC114 Aislador para torre.

*La punta tipo dipolo ofrece un cono de protección de 72° debajo del serpentín. Se recomienda para zonas de baja incidencia de rayos.
*Se recomienda cable de cobre calibre 2/0 para realizar la integración (SLY-346-BLK). Considerando una instalación del electrodo a máximo 3 metros de la torre se usan aprox. 8 metros.

Ver diagrama de conexión de Tierra Física + Pararrayo en el siguiente DIAGRAMA.

Recomendaciones:

  • Asegúrese de que la instalación sea realizada por un profesional capacitado.
  • Programe un plan de mantenimiento para revisión de tensiones en retenidas y ajuste de tornillería.
  • No instalar paneles solares a más de 6 metros de altura. Revisar la compatibilidad entre celdas solares y montajes.
  • Debe de realizarse un estudio de esfuerzos cuando se coloque una carga excéntrica en torre. Ésta puede causar torsión y flexión excesiva en torre causando fallas estructurales.
  • La torre debe ser pintada en tono naranja-rojizo y blanco, en 7 franjas de igual altura empezando y terminando en naranja-rojizo (SYSCOM no realiza el trabajo de pintura de la torre).
  • Se recomienda iluminar la torre al menos en la punta con una lámpara color rojo.

Diagrama Representativo: Instalación de Retenida Versión 2.0

Diagrama de instalación de retenida

Imágenes de Instalación

Imágenes de instalación

Descarga la ficha técnica aquí

Logo SYSCOM TOWERS

Outstanding Features:

  • Product manufactured under ISO 9001:2015 standards.
  • High Elevation / Low Cost.
  • 100% Inspection of Section-to-Section Assembly.
  • Hot-dip galvanized according to NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal areas or industrial areas.

Physical Characteristics:

  • Maximum Axial Load: 350 kg.
  • Height: 12 meters (4 sections).
  • Wind resistance: 200 km/hr.
  • Corrosion protection: Hot-dip galvanizing (NMX-H-004-SCFI-2008).
  • Application: Outdoors (Humid areas).

Includes the following components:

Quantity Model Description
4 STZ35G Tower section, 35 cm face width.
1 SCZ35PG 35 cm tower top with suppressor for lightning rod.
1 SBZ35G 35 cm tower base.
1 SAB45G Anchor for 35/45 tower base.
2 SJB35G Guy wire clamp.
3 SAZ45G Ground anchor for Guy wire.
12 CUELLO-14-HDG Thimble for guy wire
36 NUDO-316-FJG 3/16' cable clip.

Guy wire not included. 95 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.

Turnbuckles not included. 6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will result in loss of equipment warranty, and any additional adaptations are the responsibility of the installer.


Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. L810 type.
2 HLU3R2 Mounting for EIGSLSE obstruction lamp

*The signaling standard dictates that the tower must be painted in 7 equally sized stripes; 4 stripes in reddish-orange and 3 in white.

Lifeline System (Not included)

Quantity Model Description
1 SHE-LV Pair of fastening hardware
1 S-GULV Line guide
15 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged clip
2 CUELLO-38-HDG 3/8' Thimble
1 TRY-ACC-SLIDER (Optional) Safety Trolley for Installer.
1 SYS-USA7B (Optional) Suspension Harness.

*NOM-009 mandates the use of systems that prevent accidental falls on a structure.

Recommended Grounding System for Tower and Equipment Mounted on it (Not included)

Quantity Model Description
1 TG45AB 45 A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box.
3 TGCR11 Eye Connector
2 TGAB18 Rod Connector
1 TGBUSG10 Busbar with 1000A Insulators (Without Enclosure)

* It is recommended to use 4 AWG insulated copper cable (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.

Recommended Basic Lightning Rod System for Tower (Not included)

Quantity Model Description
1 TGTDPC Punta Pararrayo con Mástil de Aluminio (MASTIL1.2)
1 TG45AB Electrodo de 45 Amp. Con un saco de compuesto mejorador de impedancia (H2OHM), brújula y nivel.
1 S610 Registro plástico chico.
1 ANTIOX Aerosol para protección de terminales.
3 TGCR11 Conector de Ojo.
2 TGAB18 Conector para Varilla.
8 TGAC114 Aislador para torre.

*La punta tipo dipolo ofrece un cono de protección de 72° debajo del serpentín. Se recomienda para zonas de baja incidencia de rayos.
*Se recomienda cable de cobre calibre 2/0 para realizar la integración (SLY-346-BLK). Considerando una instalación del electrodo a máximo 3 metros de la torre se usan aprox. 8 metros.

Ver diagrama de conexión de Tierra Física + Pararrayo en el siguiente DIAGRAMA.

Recomendaciones:

  • Asegúrese de que la instalación sea realizada por un profesional capacitado.
  • Programe un plan de mantenimiento para revisión de tensiones en retenidas y ajuste de tornillería.
  • No instalar paneles solares a más de 6 metros de altura. Revisar la compatibilidad entre celdas solares y montajes.
  • Debe de realizarse un estudio de esfuerzos cuando se coloque una carga excéntrica en torre. Ésta puede causar torsión y flexión excesiva en torre causando fallas estructurales.
  • La torre debe ser pintada en tono naranja-rojizo y blanco, en 7 franjas de igual altura empezando y terminando en naranja-rojizo (SYSCOM no realiza el trabajo de pintura de la torre).
  • Se recomienda iluminar la torre al menos en la punta con una lámpara color rojo.

Diagrama Representativo: Instalación de Retenida Versión 2.0

Diagrama de instalación de retenida

Imágenes de Instalación

Imágenes de instalación

Descarga la ficha técnica aquí