Kit Pararrayo con Punta en Aluminio con Accesorios para Protección de 160 m de Diámetro.
- SKU KIT-MASTER-01-V2
- Categoria Energía / Herramientas > Calidad de la Energía > Pararrayos
The KDA-01 lightning rod system is a lightning protection system (LPS). It serves to intercept, conduct, and dissipate lightning current and internal elements through bonding, shielding, and grounding. The objective of an LPS is to reduce the risk of damage to people and other living beings, as well as structures, buildings, and their contents.
Offers 160m protection diameter.
Included Components
| Quantity | Model | Description |
|---|---|---|
| 1 | KDA01ALU | Lightning rod with 1.2m mast. 100 A electrode (TG100K). 11 Kg bag of soil enhancer (H2OHM). |
| 5 | TGCR14 | Bronze Connector. |
| 2 | TGAB18 | Rod Connector. |
| 1 | ANTIOX | Protective spray for connectors. |
| 1 | S610 | Electrode housing. |
| 1 | BP/M2 | Flat Base with Integrated 2m Mast for Lightning Rod. |
Complementary accessories (Not included)
Description of KDA01 Tip
Lightning rod and current conductor tip designed in highly conductive aluminum, which is part of an external lightning protection system (ELPS), to reduce the risk of damage that lightning can cause.
Seeks to reduce the incidence of fall by up to 95% due to its magnetoactive operation.
It is recommended to take into account the NMX-J-549-ANCE-2005 Standard, which suggests that a lightning protection system (LPS) must have an internal lightning protection system (ILPS) and an external lightning protection system (ELPS).
The KDA-01 tip is part of the external protection, while the internal part corresponds to the transient surge suppressors (TSS) of the TOTAL GROUND brand.
Webinars
Basic course for selection and implementation of protection systems
WEBINAR 1: BASIC PHYSICAL GROUNDS AND LIGHTNING RODS (STARTS AT MIN. 14).
WEBINAR 2: INSTALLATION OF PHYSICAL GROUNDS AND LIGHTNING RODS.
WEBINAR 3: TOTAL GROUND LIGHTNING ROD SYSTEMS
The KDA-01 lightning rod system is a lightning protection system (LPS). It serves to intercept, conduct, and dissipate lightning current and internal elements through bonding, shielding, and grounding. The objective of an LPS is to reduce the risk of damage to people and other living beings, as well as structures, buildings, and their contents.
Offers 160m protection diameter.
Included Components
| Quantity | Model | Description |
|---|---|---|
| 1 | KDA01ALU | Lightning rod with 1.2m mast. 100 A electrode (TG100K). 11 Kg bag of soil enhancer (H2OHM). |
| 5 | TGCR14 | Bronze Connector. |
| 2 | TGAB18 | Rod Connector. |
| 1 | ANTIOX | Protective spray for connectors. |
| 1 | S610 | Electrode housing. |
| 1 | BP/M2 | Flat Base with Integrated 2m Mast for Lightning Rod. |
Complementary accessories (Not included)
| Quantity | Model | Description |
|---|---|---|
| -- | SLY346BLK | THW-LS Coated Copper Cable Gauge 2/0 AWG. |
| 1 | TGCDA | Atmospheric Discharge Counter. |
| -- | TGAC o TGAC114 | Downcomer cable insulator. |
Description of KDA01 Tip
Lightning rod and current conductor tip designed in highly conductive aluminum, which is part of an external lightning protection system (ELPS), to reduce the risk of damage that lightning can cause.
Seeks to reduce the incidence of fall by up to 95% due to its magnetoactive operation.
It is recommended to take into account the NMX-J-549-ANCE-2005 Standard, which suggests that a lightning protection system (LPS) must have an internal lightning protection system (ILPS) and an external lightning protection system (ELPS).
The KDA-01 tip is part of the external protection, while the internal part corresponds to the transient surge suppressors (TSS) of the TOTAL GROUND brand.
Webinars
Basic course for selection and implementation of protection systems
WEBINAR 1: BASIC PHYSICAL GROUNDS AND LIGHTNING RODS (STARTS AT MIN. 14).
WEBINAR 2: INSTALLATION OF PHYSICAL GROUNDS AND LIGHTNING RODS.
WEBINAR 3: TOTAL GROUND LIGHTNING ROD SYSTEMS
Basic course for selection and implementation of protection systems