Módulo solar de 130 W, 12 VCC, monocristalino, 36 celdas grado A
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

Módulo solar de 130 W, 12 VCC, monocristalino, 36 celdas grado A

Disponible: En Stock
$ 1,038.76 MXN
Image

New Technology

  • Encapsulated in transparent EVA and 3.2 mm tempered glass
  • Back protected with UV-resistant TEDLAR
  • Laminates mounted on anodized aluminum frame

Applications

  • Radio communication repeater stations
  • Electrification in rural areas
  • Emergency communication systems
  • Power supply for medical equipment in rural areas
  • Water pumping systems
  • Obstruction lights for air traffic
  • Cathodic protection systems
  • Railway signaling

Warranty

Against manufacturing defects and 40 years of useful life.

Maintenance

Solar panels are equipment with very low or no maintenance. It is not recommended to open the diode box as they are sealed; if it is strictly necessary to do so, follow these steps:

With a fine-tipped flathead screwdriver, unlatch the plastic clips in the opposite direction and carefully remove the cover from top to bottom as shown in the video.

Technical Specifications
  • Maximum Power: 130 W (±3%)
  • Voltage: 20.2 V (±3%)
  • Amperage: 6.44 A (±3%)
  • Open Circuit Voltage (Voc): 24 V (±3%)
  • Short Circuit Current (Isc): 7 A (±3%)
  • Dimensions: 885 x 765 x 30 mm
  • Weight: 7.2 kg
  • Ambient Temperature: -40 to 85 ºC
  • Maximum System Voltage: 1000 V
Warranty Recommendations
  • Any claim must be made within the warranty period with the invoice
  • The serial number and back label must be visible
  • Cutting MC-4 connectors voids the warranty
  • Do not install in shaded areas, considered a bad installation
  • Do not mix modules of different powers in the same controller or inverter
  • It is recommended to use EP-MC4 crimping pliers for EPL01 connectors
Additional Information

Note: Electrical specifications are indicated under an irradiance of 1000 W/m² and a temperature of 25 ºC.

Installation Comment:

To avoid damage to the module cable connection, you must put cable ties (plastic covers) on the cable when installing it so that they are not loose, the weight of the cable and the wind can damage the diode box


Download the technical sheet here

New Technology

  • Encapsulated in transparent EVA and 3.2 mm tempered glass
  • Back protected with UV-resistant TEDLAR
  • Laminates mounted on anodized aluminum frame

Applications

  • Radio communication repeater stations
  • Electrification in rural areas
  • Emergency communication systems
  • Power supply for medical equipment in rural areas
  • Water pumping systems
  • Obstruction lights for air traffic
  • Cathodic protection systems
  • Railway signaling

Warranty

Against manufacturing defects and 40 years of useful life.

Maintenance

Solar panels are equipment with very low or no maintenance. It is not recommended to open the diode box as they are sealed; if it is strictly necessary to do so, follow these steps:

With a fine-tipped flathead screwdriver, unlatch the plastic clips in the opposite direction and carefully remove the cover from top to bottom as shown in the video.

Technical Specifications
  • Maximum Power: 130 W (±3%)
  • Voltage: 20.2 V (±3%)
  • Amperage: 6.44 A (±3%)
  • Open Circuit Voltage (Voc): 24 V (±3%)
  • Short Circuit Current (Isc): 7 A (±3%)
  • Dimensions: 885 x 765 x 30 mm
  • Weight: 7.2 kg
  • Ambient Temperature: -40 to 85 ºC
  • Maximum System Voltage: 1000 V
Warranty Recommendations
  • Any claim must be made within the warranty period with the invoice
  • The serial number and back label must be visible
  • Cutting MC-4 connectors voids the warranty
  • Do not install in shaded areas, considered a bad installation
  • Do not mix modules of different powers in the same controller or inverter
  • It is recommended to use EP-MC4 crimping pliers for EPL01 connectors
Additional Information

Note: Electrical specifications are indicated under an irradiance of 1000 W/m² and a temperature of 25 ºC.

Installation Comment:

To avoid damage to the module cable connection, you must put cable ties (plastic covers) on the cable when installing it so that they are not loose, the weight of the cable and the wind can damage the diode box


Download the technical sheet here